Modular Block System: Hydraulic Presses
Standard Function Blocks
SB069
SB069: Monitoring ESPE/AOPDs with guarding function
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 600
Format: Byte constants KF000001 ... KF000600
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
Value of DW (SSNR) = 0: No error found
•
GRP
Status flag of the I/O-Group (SafetyBUS p) whose I/O signals
are used for this function (M116.00 for I/O-Group 0 to M116.31
for I/O-Group 31). If the SB is being used without SafetyBUS
p, the input parameter must be assigned RLO-1.
•
NO_1:
Output signal 1 from the ESPE/AOPD (normally open 1)
NO_1 = 0: Protected field broken
NO_1 = 1: Protected field clear
•
NO_2:
Output signal 2 from the ESPE/AOPD (normally open 2)
NO_2 = 0: Protected field broken
NO_2 = 1: Protected field clear
•
GdOn:
Guard Only mode of ESPE/AOPD
GdOn = 0
Guard function of ESPE/AOPD is deactivated,
i.e. the ESPE/AOPD is switched off.
GdOn = 1
ESPE/AOPD is operating as a guarding device.
The signal can come from a connected operating mode
selector switch.
SB 069
AOPD_GDO
W- SSNR
X - GRP
X - NO_1
X - NO_2
X - GdOn
B - MTD
X - SSeq
X - ARSt
X - Test
X - RSET
ENBL -
X
TEST -
X
PWR
-
X
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license