Sb067: feedback loop monitoring (rfk) – Pilz PSS SB HYD, Basic license User Manual
Page 295

9-7
Modular Block System: Hydraulic Presses
Changes from Version 1.0 to Version 1.1
• Transposition of error bit 12 and 13 rectified
• Automatic start now possible when PSS cold/warm starts
i.e. no start-up disabler, no function test and no reset required.
SB067: Feedback loop monitoring (RFK)
Version
Date
CRC
1.0
04.06.96
F309
1.1
30.05.97
71A5
STOP
Changes from Version 1.0 to Version 1.1
• Transposition of error bits 04 and 05 rectified
• Transposition of error bits 06 and 07 rectified
• Notation of input parameter “
SSNr ”changed to “ SSNR”.
SB068: Monitoring ESPE/AOPDs with guarding function
Version
Date
CRC
1.0
10.10.95
148E
1.1
31.07.97
A3A0
STOP
1.2
21.01.68
6509
STOP
1.3
07.05.98
4724
Changes from Version 1.0 to Version 1.1
• Name changed from “BWS_ÜW” to “BWS_AOS”
• When the protected field is clear, the SB now expects two 1-signals from
the ESPE/AOPD (version 1.0: one 0-signal and one 1-signal)
This means that input parameters
BWSö and BWSs have been replaced
by input parameters
NO_1 and NO_2.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license