Modular Block System: Hydraulic Presses

Standard Function Blocks

SB072

- Bit 14:

RSet input constantly high or set too early
Remedy: Check switch, cable, input card and all conditions,
and then reset.

- Bit 15:

ESPE/AOPD is clear, confirm with

RSET.

• Error messages on the CPU-display

- None

Global parameters used in administration data block DB015

Global parameters may be set in OB120 using SB070.

- DW1001: Contact synchronisation time of 2 N/O contacts

(NO_1 and NO_2 of the ESPE/AOPD)

- DW1022: Minimum PSS scan time

Blocks required

• DB015:

Administration data block

DB015 must consist of its total length of 1024 data words.
DB015 must have READ/WRITE access.