Sb097: monitoring muting lamps, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual
Page 226: Standard function blocks sb097

6-164
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB097
SB097: Monitoring muting lamps
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
•
GRP:
On SafetyBUS p applications:
Assign the status flag of the I/O-Group containing inputs
FbL1
and
FbL2 (M 116.00 for I/O-Group 0 to M 116.31 for
I/O-Group 31).
On non-SafetyBUS p applications::
Assign RLO-1 (M 110.01)
•
ON:
Enable signal for muting lamps “ON”
ON = 1: Switch on muting lamps
ON = 0: Switch off muting lamps
This input should be assigned the output signal MAct from
SB 072 (Muting).
•
FbL1:
Feedback input for monitoring filament 1
(Feedback Loop 1)
•
FbL2:
Feedback input for monitoring filament 2
(Feedback Loop 2)
•
RSET:
Input for acknowledging error messages (Reset)
RSET = 0/1-pulse edge: Delete all error entries when the faults
have been rectified.
SB097
MUT_LAMP
B - SSNR
X - GRP
X - ON
X - FbL1
X - FbL2
X - 1OUT
X - RSET
ENBL - X
WARN - X
LMP1 - X
LMP2 - X
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license