Function – Pilz PSS SB HYD, Basic license User Manual
Page 125

Modular Block System: Hydraulic Presses
6-63
•
TEST:
Test output
TEST = 0: Simulated break in protected field
Automatic function test of ESPE/AOPD by
switching off the ESPE/AOPD emitter (see also
under “Function”).
TEST = 1: ESPE/AOPD emitter in operation
•
RdCy:
ESPE/AOPD ready for new cycle
RdCy = 0:
Cycle mode not selected or cycle mode selected
but ESPE/AOPD not ready for break
RdCy = 1:
Cycle mode selected and ESPE/AOPD ready for
break
•
PWR:
Output for switching the operating voltage to the ESPE/AOPD
(POWER)
PWR = 0:
ESPE/AOPD switched off
(input parameter:
OFF = 1; RUN irrelevant)
PWR = 1:
ESPE/AOPD switched on
(input parameter:
GdO or SBrk or DBrk = 1;
RUN irrelevant)
Function
• Monitoring the ESPE/AOPD inputs:
Feasibility check on N/O 1 and N/O 2 (input parameters
NO_1 and
NO_2), monitoring contact synchronisation time (DB 015/DW 1001).
• Reset pulse edge
Existing errors can be reset via a 0/1-pulse edge at the reset button
(input parameter
RSET).
• Function test:
A function test is carried out by breaking the protected field, clearing it
again and then pressing the reset button (input parameter
RSET).
In the case of hardware errors, a function test must always be carried out
after the error has been rectified.
• Start-up disabler:
A start-up disabler will be set if the PSS is switched on or monitoring of
the ESPE/AOPD is activated via the input parameter
RUN.
The lifting of the disable will depend on the set start-up procedure. The
start-up sequence is established via the input parameter
SSeq (function
test or just reset in “Guard only” mode).
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license