Modular Block System: Hydraulic Presses
Feedback loop monitoring (selective shutdown), category 4
Block used: SB067/RFK_K4
WARNING!
If only one contactor is used to switch a potentially dangerous drive, it
must be possible to switch this contactor off via a group contactor situated
within the current path. This group contactor must be controlled with the
AND-linked FG-signals of the individual main contactors and must be
monitored with a feedback loop.
The subordinate main contactors may only switch on if the group contactor
monitor
FG = 1. The switch-on signal from the subordinate contactors
must form an AND-connection with the FG-signal from the group contactor
and must be assigned to the
Ein-parameter of the main contactor monitor.
If only one feedback loop is used, the feedback input will be connected to
RFK1 and RFK2.
Please note:
The feedback loops must be wired inside the control cabinet. If this is not
possible, the feedback loops must be pulsed.
Fig. 8-9: Wiring diagram
L1
24 V
N
M1.1
K-M1.1
K-G1
RFK
K-M1.1
E0.0
E0.1
PSS
+ A1.16 -
K-M1.1
K-M1.2
M1.2
K-M1.2
E0.8
RFK
K-G1
M1.1
START
RFK
K-M1.2
E0.2
E0.9
M1.2
START
K-G1
0 V
M
M
+ A1.17 -
+ A1.18 -
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license