Modular Block System: Hydraulic Presses

6-59

GdO:

Guard only mode of ESPE/AOPD
OFF = 0
GdO = 1

ESPE/AOPD has guarding function and reset lock.

SBrk = 0

The signal must come from a connected

DBrk = 0

operating mode selector switch block (SB 51/52)

SBrk:

Single break mode of ESPE/AOPD
OFF = 0

Enable via single break of ESPE/AOPD

GdO = 0

(output parameter

ENBL).

SBrk = 1

The signal must come from a connected

DBrk = 0

operating mode selector switch block (SB 51/52)

DBrk:

Double break mode of ESPE/AOPD
OFF = 0

Enable via double break of ESPE/AOPD

GdO = 0

(output parameter

ENBL).

SBrk = 0

The signal must come from a connected

DBrk = 1

operating mode selector switch block (SB 51/52)

RUN:

Static enable (

StFG) for operating the ESPE/AOPD

RUN = 0:

Not enabled

RUN = 0/1-pulse edge: Runs in accordance with the pre-

selected run mode (see input parameter

SSeq)

SSeq = 0: Function test required
SSeq = 1: Reset required

RUN = 1:

Enable

INFORMATION
The output parameter

PWR which switches the supply voltage

to the ESPE/AOPD will remain high even when

RUN = 0.

CyRs:

Cycle reset
This parameter is only effective in single break (

SBrk) or

double break (

DBrk) mode.

CyRs = 0/1-pulse edge: Resets the cycle time counter and

sets the cycle lock for the first cycle

On presses for example, assign input parameter

CyRs the

signal from top dead centre (TDC), i.e.:

CyRs = 0:

On the dangerous downward movement

CyRs = 1:

CyRs = 1: At top dead centre (TDC)

In addition, the combination of all the safety enables from
emergency stop buttons, start-up disablers etc. should have
the following effect on input parameter

CyRs: when the device

is operated in a downward movement (

ENBL = 1), a 0/1-pulse

edge at input parameter

CyRs will reset and therefore restart

the cycle time counter.