Blocks contained in the administration data blocks – Pilz PSS SB HYD, Basic license User Manual
Page 53

5-5
Modular Block System: Hydraulic Presses
Blocks contained in the administration data blocks
Each standard function block occupies 1 data word per block (see
Fig. 5-2). This means a max. of 200 safety devices (e.g. E-STOP 1, E-
STOP 2, safety gate 1) can be managed per administration data block.
The PSS uses a standard function block’s SSNR to automatically generate
the corresponding data words (see section entitled “Input parameter
SSNR”).
DB017
DB016
DW0000
DB015
Block 1
Block 2
Block 3
Block 4
Block 5
Block 6
Global
parameters
Data word 1
Data word 2
Data word 3
Data word 4
Data word 5
Data words 1 to 5
of an MBS
standard function block
Fig. 5-2: Contents of the administration data blocks
This manual is related to the following products:
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license