SB097: Monitoring muting lamps
SB097 is a standard function block for controlling and monitoring two
redundant muting lamps, up to and including category 4 in accordance
with EN 954-1, 03/97.
Application and use:
SB097 can be used for the following applications:
• Displaying muting status in accordance with EN 61496-1, 06/98.
• Connecting muting lamps to single-pole outputs.
• Controlling two redundant muting lamps (24 V incandescent lamps).
• Monitoring muting lamps for a break in the filament.
• Defective muting lamps can be exchanged while the plant is running.
• Removing the enable when the second filament blows.
• Can be used with just one output.
Positive-switching: 1 output. Negative-switching: 2 outputs.
INFORMATION
This block undertakes muting safety functions in conjunction with the block
SB072. When using this block you must comply with the relevant
standards and regulations, in particular EN 61496-1, 06/98.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license