5-14
MBS Basics
Modular Block System: Hydraulic Presses
DW1001
Number of cycles in the contact synchronisation time between
2 N/O contacts or 2 N/C contacts (e.g. E-STOP button, reset
key, etc.)
{CoSy : 50 ms}
DW1002
Number of cycles in the feedback loop’s reaction time to a
change in the PSS output connected to the main contactor
{RFbL : 100 ms}
DW1003
Number of cycles in the contact switchover time between a
N/O and N/C contact (pushbutton)
{CS_B : 100 ms}
DW1004
Number of cycles in the contact switchover time between a
N/O and N/C contact (relay)
{CS_R: 50 ms}
DW1005
Number of cycles in the machine clock time
{MaCy : max. 30 s in accordance with EN 61496-1 section
A.8.4, 06/98}
DW1006
Number of cycles in the permitted ESPE reaction time
{ESPE : max. 150 ms in accordance with EN 61496-1 section
5.2.4, 06/98}
DW1007
Reserved
DW1009
Reserved
DW1010
Reserved
DW1011
Reserved
DW1012
Reserved
DW1013
Reserved
DW1014
Reserved
DW1015
Counter for monitoring the SSNR
DW1016
Reserved
DW1017
Reserved
DW1018
Reserved
DW1019
Reserved for administration
DW1020
Reserved
DW1021
Reserved for burner management
DW1022
Min. scan time from DB002/DW0002
DW1023
Reserved
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license