Error messages, Blocks required – Pilz PSS SB HYD, Basic license User Manual
Page 225

Modular Block System: Hydraulic Presses
6-163
Error messages
Any fault that is detected will be stored in the corresponding error data
word (
SSNR) of DB015 (1st data block), until the fault has been fully dealt
with.
• Error messages in DB015
- Bit 00:
Enable switch is fully operated (E-STOP)
Remedy: Release enable switch, check switch, cable, input
card and all conditions, and then reset (input parameter
RSET).
- Bit 01:
N/O contact on the enable switch is defective (input parameter
NO)
Remedy: Check switch, cable, input card and all conditions,
and then reset (input parameter
RSET).
- Bit 08:
RSET input constantly high or set too early
Remedy: Check switch, cable, input card and all conditions,
and then reset (input parameter
RSET).
- Bit 09:
RSET input not yet operated, no reset present
Remedy: Press reset button (input parameter
RSET)
• Error messages on the CPU-display
- None
Global parameters used in administration data block DB015
• None
Blocks required
• DB015:
Administration data block
DB015 must consist of its total length of 1024 data words
DB015 must have READ/WRITE access.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license