beautypg.com

Error messages, Blocks required – Pilz PSS SB HYD, Basic license User Manual

Page 225

background image

Modular Block System: Hydraulic Presses

6-163

Error messages

Any fault that is detected will be stored in the corresponding error data
word (

SSNR) of DB015 (1st data block), until the fault has been fully dealt

with.

• Error messages in DB015

- Bit 00:

Enable switch is fully operated (E-STOP)
Remedy: Release enable switch, check switch, cable, input
card and all conditions, and then reset (input parameter
RSET).

- Bit 01:

N/O contact on the enable switch is defective (input parameter
NO)
Remedy: Check switch, cable, input card and all conditions,
and then reset (input parameter

RSET).

- Bit 08:

RSET input constantly high or set too early
Remedy: Check switch, cable, input card and all conditions,
and then reset (input parameter

RSET).

- Bit 09:

RSET input not yet operated, no reset present
Remedy: Press reset button (input parameter

RSET)

• Error messages on the CPU-display

- None

Global parameters used in administration data block DB015

• None

Blocks required

• DB015:

Administration data block

DB015 must consist of its total length of 1024 data words
DB015 must have READ/WRITE access.