Modular Block System: Hydraulic Presses
SB063: Emergency stop monitoring
SB063 is a standard function block for monitoring E-STOP buttons up to
category 4, in accordance with EN 954-1, 03/97 and AK 6, in accordance
with DIN V 19 250, 05/94. It is also possible to use SB063 to monitor
safety gates up to category 4, in accordance with EN 954-1, 03/97.
INFORMATION
On SB063, the SSNR may lie in the range of 1 to 600.
Operating modes:
• With or without start-up reset on cold start or on a SafetyBUS p group
start
• With or without automatic reset when E-STOP is released
• With or without prompt for function test after a synchronisation error
when the E-STOP is released
INFORMATION
Input circuitry:
• Use E-STOP button with test pulses
• When using SB063 for category 4 applications:
- use dual-channel elements
• When using SB063 for category 2 applications:
- use single-channel elements
SB064: Safety gate monitoring
SB064 is designed for monitoring a safety gate. It can monitor a safety
gate with one or two switches.
SB064 meets all the requirements up to category 4, in accordance with
EN 954-1, 03/97. The block is designed in such a way that it can be used
generally to monitor the synchronisation of two signals and contact
welding.
INFORMATION
On SB064, the SSNR may lie in the range of 1 to 600.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license