Intended use – Pilz PSS SB HYD, Basic license User Manual
Page 40

4-10
Intended Use
Modular Block System: Hydraulic Presses
SB069: Monitoring ESPE/AOPDs with guarding function
SB069 is a standard function block which is designed to monitor ESPE/
AOPDs up to category 4, in accordance with EN 954-1, 03/97, with
guarding function.
INFORMATION
On SB069, the SSNR may lie in the range of 1 to 600.
Features:
• Monitors the ESPE/AOPD outputs: feasibility check on the contact
switchover time of the two N/O contacts
• Start-up disabler
• Reset lock
• Test mode
• Parameter to suppress error messages when an I/O-Group stops
(SafetyBUS p)
Operating modes
• Guard function of ESPE/AOPD is deactivated (ESPE/AOPD switched
off)
• ESPE/AOPD as guarding device with reset lock
INFORMATION
This block performs safety functions.
When using this block you must comply with the relevant standards and
regulations, in particular:
• EN 61 496-1, 06/98
• Regulations laid down by the manufacturer of your ESPE/AOPD
INFORMATION
Input circuitry: Category 4 ESPE/AOPDs with semiconductor outputs must
be connected to DI 2 inputs (e.g. input module PSS(1) DI 2) in order to
meet the requirements of category 4.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license