Intended Use

Modular Block System: Hydraulic Presses

SB069: Monitoring ESPE/AOPDs with guarding function

SB069 is a standard function block which is designed to monitor ESPE/
AOPDs up to category 4, in accordance with EN 954-1, 03/97, with
guarding function.

INFORMATION

On SB069, the SSNR may lie in the range of 1 to 600.

Features:

• Monitors the ESPE/AOPD outputs: feasibility check on the contact

switchover time of the two N/O contacts

• Start-up disabler

• Reset lock

• Test mode

• Parameter to suppress error messages when an I/O-Group stops

(SafetyBUS p)

Operating modes

• Guard function of ESPE/AOPD is deactivated (ESPE/AOPD switched

off)

• ESPE/AOPD as guarding device with reset lock

INFORMATION
This block performs safety functions.
When using this block you must comply with the relevant standards and
regulations, in particular:
• EN 61 496-1, 06/98

• Regulations laid down by the manufacturer of your ESPE/AOPD

INFORMATION
Input circuitry: Category 4 ESPE/AOPDs with semiconductor outputs must
be connected to DI 2 inputs (e.g. input module PSS(1) DI 2) in order to
meet the requirements of category 4.