Pilz PSS SB HYD, Basic license User Manual
Page 151

Modular Block System: Hydraulic Presses
6-89
•
MS2:
N/O contact of Muting signal Serial 2
MS2 = 0:
Not operated (muting signal off)
MS2 = 1:
Operated (muting signal on)
•
MP1:
N/O contact of Muting signal Parallel 1
MP1 = 0:
Not operated (muting signal off)
MP1 = 1:
Operated (muting signal on)
•
MP2:
N/O contact of Muting signal Parallel 2 or (inverted) N/C
contact with sensors (please refer to “Safety guidelines” in the
SB description)
MP2 = 0:
Not operated (muting signal off)
MP2 = 1:
Operated (muting signal on)
•
TS12:
Time Sequential
This setting determines the maximum time that can elapse
between the operation (0/1-pulse edge) of MS1 and MS2.
Permitted value range: 0 ... 32 767
Format:
Word
Time unit:
ms
•
TPSy :
Timer Parallel Synchronisation
This setting determines the maximum time (synchronisation
time) that can elapse between the operation (0/1-pulse edge)
of MP1 and MP2.
Permitted value range: 0 ... 2047
Format:
Word
Time unit:
ms
•
TInt:
Timer Interrupt
This setting determines:
- the maximum permitted release time of the ESPE/AOPD or
- the maximum interrupt time of MP1 or MP2
during active
muting
Permitted value range: 0 ... 2047
Format:
Word
Time unit:
ms
While muting is activated in sequential mode and
MS2 = MP1 = 1 (MS1 and MP2 irrelevant), the ESPE/AOPD
may be released without the muting function being switched
off (e.g. during gaps in the load). If only MS2 = 1 (MP1 = 0,
MS1 and MP2 irrelevant), the ESPE/AOPD may only be
released for the time stated under
TInt.
Sequential muting will be switched off when
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license