Sb059: two-hand monitoring, Sb061: emergency stop monitoring, Intended use – Pilz PSS SB HYD, Basic license User Manual
Page 34

4-4
Intended Use
Modular Block System: Hydraulic Presses
SB059: Two-hand monitoring
The function of standard function block SB059 is determined in
accordance with EN 574, 02/97. It fulfils all the requirements of category 4,
in accordance with EN 954-1, 03/97.
Operating modes:
• Monitoring two buttons (N/C and N/O) in accordance with
EN 954-1, 03/97
• Monitoring the synchronisation time of two buttons (<0.5 s)
• Can also be used to monitor foot switches
INFORMATION
Input circuitry:
• Two-hand buttons must use test pulses.
SB061: Emergency stop monitoring
SB061 is a standard function block for monitoring E-STOP buttons up to
category 4, in accordance with EN 954-1, 03/97 and AK 6, in accordance
with DIN V 19 250, 05/94. It is also possible to use SB061 to monitor
safety gates up to category 4, in accordance with EN 954-1, 03/97.
Operating modes:
• With or without start-up reset on cold-start
• With or without automatic reset when E-STOP is released
INFORMATION
Input circuitry:
• Use E-STOP button with test pulses
• When using SB061 for category 4 applications:
- use dual-channel elements
• When using SB061 for category 2 applications:
- use single-channel elements
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license