Pilz PSS SB HYD, Basic license User Manual
Page 95

Modular Block System: Hydraulic Presses
6-33
•
MRun:
Machine is running
MEin = 0:
Machine standing
MEin = 1:
Machine is running
MEin = 1/0-pulse edge: Activate reset lock.
This parameter can force the operator to carry out a function
test of the gate (gate open/closed).
The reset lock is lifted by carrying out a function test on the
gate followed by the
RSET signal.
•
AuSt:
Automatic start/start-up disabler
AuSt = 0:
Start-up disabler (initial reset is required)
AuSt = 1:
Automatic start/no start-up disabler on PSS cold/
warm start or when starting the I/O-Group; only
effective in conjunction with
NoFT = 1 (see also
under “Operating modes”)
•
ARSt:
Automatic restart/reset lock
ARSt = 0:
Reset lock (reset is required)
ARSt = 1:
Automatic restart/no reset lock
(see also under “Operating modes”)
•
NoFT:
Function test on the gate
NoFT = 0:
Function test required on the gate
NoFT = 1:
Cold/warm start without function test on the gate
(see also under “Operating modes”)
•
RSET:
Reset input
RSET = 0/1 pulse edge:
- Reset errors or
- Reset start-up disabler or
- Reset reset lock
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license