Modular Block System: Hydraulic Presses
Standard Function Blocks
SB088: Driving/monitoring the position of a dual hydraulic valve
(poppet and directional control valve)
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
Value of DW (
SSNR) = 0: No error found
•
ON:
Start signal for “drive valves” (Y1 and Y2)
ON = 0:
Valves switched off
ON = 0/1 pulse edge: Switch valves on
ON = 1:
Valves switched on
ON = 1/0 pulse edge: Switch valves off
The valves cannot be switched on if the block has detected a
fault (reset lock).
The valves can only be switched on if they are in their start
(off) position (see input parameters
S1 and S2).
•
S1:
Acknowledgement of valve position (valve 1)
S1 = 1:
Valve in its start position (valve de-energised,
acknowledgement from valve is present)
•
S2:
Acknowledgement of valve position (valve 2)
S2 = 1:
Valve in its start position (valve de-energised,
acknowledgement from valve is present)
SB088
H_VALV_D
B - SSNR
X - ON
X - S1
X - S2
W - TOn
W - TOff
X - Y1On
X - Y2On
X - VTyp
X - RSET
ENBL - X
Y1
- X
Y2
- X
ERR - X
SB088
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license