8-35
Modular Block System: Hydraulic Presses
Program:
KB 017
-
E 0.00
.Gate switch 1.1
-
E 0.01
.Gate switch 1.2
-
KF 01000 .Sync. time
-
M 110.00 .RLO-0
-
E 0.03
.Reset
-
M 110.00 .Reset lock
-
M 110.00 .Start-up disabler
-
M 110.01 .No F-Test
-
KB 018
-
E 0.04
.Gate switch 2.1
-
E 0.05
.Gate switch 2.2
-
KF 01000 .Sync. time
-
M 110.00 .RLO-0
-
E 0.06
.Reset
-
M 110.00 .Reset lock
-
M 110.00 .Start-up disabler
-
M 110.01 .No F-Test
:L
M 80.00
.FG_ST1
:U
M 80.01
.FG_ST2
:=
M 80.02
.FG_GES_ST
SB 066
ST_K4
B - SSNR
X - S1
X - S2
W - SyTi
X - MEin
X - Strt
X - ARSt
X - AuSt
X - NFkT
FG - X - M 080.00 .FG_ST1
SB 066
ST_K4
B - SSNR
X - S1
X - S2
W - SyTi
X - MEin
X - Strt
X - ARSt
X - AuSt
X - NFkT
FG - X - M 080.01 .FG_ST2
This manual is related to the following products:
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license