Sb059: two-hand monitoring, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual
Page 78: Standard function blocks, Sb059

6-16
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB059: Two-hand monitoring
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
•
STFG:
Static enable
STFG = 0: Function disabled
STFG = 1: Function enabled
The two-hand control can only be enabled (
FG = 1) if STFG is
high. The
STFG signal is the result when all the signals that
must be present to operate the press are linked (e.g.
FG from
the E-STOP,
FG from the operating mode selector switch etc.)
•
MEin:
Machine “On”
A 1/0-pulse edge on the
MEin signal activates a lock (single-
stroke protection), which will only be lifted when the start
position is achieved (both buttons T1 and T2 released).
MEin = e.g. “Safety valve on” flag: Activation of lock required
MEin = RLO-0 (M 110.00): Activation of lock not required.
SB 059
2_HAND
B - SSNR
X - STFG
X - MEin
X - T1.2
X - T1.4
X - T2.2
X - T2.4
W- KU_S
X - RSET
X - Tipp
X - Auf
X - Off
FG
- X
GST - X
AUF - X
OFF - X
SB059
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license