Function, Standard function blocks sb092 – Pilz PSS SB HYD, Basic license User Manual
Page 222

6-160
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB092
Function
SB092 monitors a three-position enable switch designed to protect
personnel where operating modes (setup) have safety devices suspended.
It can be used for the following applications:
• For enable switches conforming to EN 1921, 10/95, VDE 2853, 07/87
• For three-position switches conforming to EN 692 section 5.3.19.4,
08/96 and EN 693 section 5.3.19.4, 2001, for presses with automatic
reset and a slow closing speed (10 mm/s)
• For the switching diagrams documented in the following pages.
INFORMATION
Please bear in mind the following points (EN 1921, 10/95):
• An enable switch approves a dangerous movement but does not actually
trigger it.
• The enable switch alone must not be able to initiate a potentially
hazardous situation.
• If an enable device is required, it must be connected to either a category
0 or category 1 stop.
• If the switching device is fed back from stage 3 through stage 2 to stage
1, the enable function in stage 2 will not occur.
• It is possible to set a start-up and reset lock after feedback from stage 3.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license