Standard function blocks sb066 – Pilz PSS SB HYD, Basic license User Manual
Page 112

6-50
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB066
Required reaction from operator in the case of a fault
Parameter
ARST
0
1
0
0
1
1
AuST
0
0
0
1
*1
0
1
*1
NFkT
0
0
1
1
1
1
Function Status of gate
open shut open shut open shut open shut open shut open shut
test
Close gate
x
-
x
-
x
-
x
-
x
-
x
-
Open and
x
*4
x
x
*4
x
x
*4
x
x
*4
x
x
*4
x
x
*4
x
close gate
Strt
-
-
-
Table 3: Reaction in the case of a fault
x Function activated or
operator reaction required
-
Function not activated or
no operator reaction required or
reset not required
Reset required via the reset input
*1
The function “No start-up disabler on PSS cold/warm start” is only
possible when no function test is set (
NFkT = 1).
*2
First close the gate, then open it and close it again.
*3
The enable can be set by opening/closing the gate or by a pulse at the
reset input.
*4
When synchronisation time S1-S2 is exceeded (error bit 09)
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license