Standard function blocks, Sb075 – Pilz PSS SB HYD, Basic license User Manual
Page 180

6-118
Modular Block System: Hydraulic Presses
Standard Function Blocks
- Bit 09:
Hazardous machine functions have not stopped
Although the hazardous machine functions were stopped and
the enable reset, the machine functions are still running.
Remedy: Check standstill monitoring, cable, input card and all
conditions and then reset (when
ARSt = 0)
- Bit 10:
Request to lock safety device when it is still open.
A request was made to lock the gate while the gate was still
open.
Remedy: Close gate or reset (when
ARSt = 0)
- Bit 11:
Gate unlocked
Remedy: Activate guard locking on gate
- Bit 12:
I/O-Group stop triggered while PSS is in RUN mode
Remedy: Start I/O-Group
- Bit 13:
Reset pressed too early
The reset button was operated (
RSET) although at least one
error was still not rectified
Remedy: Press reset button again
- Bit 14:
Reset required
Remedy: Reset
• Error messages on the CPU-display
• E003:
Administration data block has not been initialised
Remedy: Call SB071 in OB120
SB075
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license