Standard function blocks, Sb068 – Pilz PSS SB HYD, Basic license User Manual
Page 132

6-70
Modular Block System: Hydraulic Presses
Standard Function Blocks
Timing diagram for “double break” mode of ESPE/AOPD
The ESPE/AOPD is set with cycle reset (input parameter
CyRs) via a
pulse at the press TDC.
Input parameters:
RUN = 1:
Static enable for operation of the ESPE/AOPD
STyp = 0: Start-up procedure (cycle mode): first break the protected field
and then reset.
ARSt = 0: No automatic reset of the error “ESPE/AOPD interrupted” after
the protected field is cleared (reset lock).
OFF = 0
GdO = 0
Mode: Double break of ESPE/AOPD (DBrk)
SBrk = 0
DBrk = 1
A function test of the ESPE/AOPD is carried out.
The input parameter
TEST has no effect in “Guard” mode.
It is assigned RLO-0 (M110.00).
Abbreviations:
MaZy
Machine cycle time for cycling the ESPE/AOPD (30 000 ms in
accordance with EN 61 496-1 section A.8.4, 06/98).
This is a global parameter (see also under “Global parameters”
and SB070).
SB068
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license