Reset lock (input parameter arst) – Pilz PSS SB HYD, Basic license User Manual
Page 175

Modular Block System: Hydraulic Presses
6-113
Yes
x
x
x
x
x
No
x
o
o
x
/
Yes
x
x
x
x
-
No
x
o
o
x
-
Yes
No
Reset lock (
ARSt
)
Function test required (
NoFT
)
Request (
RQST
)
Open gate
Close gate
Request (
RQST
)
Reset (
RSET
)
Reset lock (input parameter
ARSt)
If the reset lock is active (
ARSt = 0), you will need to reset after each
• Opening and subsequent closing/locking of the gate (not applicable if the
gate was not opened between unlocking and locking)
• Function test
• Error
Only then can the enable be given. If no other errors are present, the
enable will be set.
If the reset lock is not active (
ARSt = 1), the enable will be set directly,
without a reset, after the above situations.
Note: This procedure is independent of the status of the input parameter
AuSt
Key:
x:
Action must be performed
o:
Action can be performed
/ :
Action does not need to be performed if the gate was not open
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license