beautypg.com

Sb059: two-hand monitoring – Pilz PSS SB HYD, Basic license User Manual

Page 293

background image

9-5

Modular Block System: Hydraulic Presses

SB059: Two-hand monitoring

Version

Date

CRC

1.0

04.06.96

75A8

1.1

15.08.97

1174

STOP

1.2

18.02.98

7380

1.3

22.03.99

9E1C

STOP

Changes from Version 1.0 to Version 1.1
• Name changed from “2_Hand” to “2_HAND”

• Addition of input parameter

Off.

This input parameter allows you to deselect two-hand monitoring or the
console.

• Addition of output parameter

OFF.

This output parameter indicates whether two-hand monitoring or the
console have been deactivated.
OFF = 1: Two-hand monitoring/console correctly deselected

Changes from Version 1.1 to Version 1.2

• Fixed contact synchronisation time implemented.

• Extended monitoring on PSS start-up/reset when two-hand monitoring /

console deselected.

Changes from Version 1.2 to Version 1.3

• Introduction of input parameter KU_S

This input parameter enables you to enter a maximum contact
switchover time between the N/O and N/C contacts on pushbuttons.

• Monitoring on PSS start-up/reset when two-hand monitoring or console

is de-selected has been optimised.