Modular Block System: Hydraulic Presses
Temporary flag range in MBS blocks
Internally, MBS blocks use the flags in the range M 64.00 ... M69.31 as
temporary flags.
NOTICE
We recommend the following:
• Do not use flags from the temporary flag range for your own applications.
Malfunctions may occur if you use the temporary flag range M64.00 ...
M69.31 for your own applications.
• If it is absolutely necessary to use this flag range, under no
circumstances should you use the flags:
- in alarm OBs
- as input parameters for standard function blocks
- as output parameters for standard function blocks
- as global parameters
Output parameter FG/ENBL
Many standard function blocks have an enable output FG/ENBL. This
output parameter indicates the enable status of a standard function block.
The enable status results from the standard function block’s check of the
inputs.
FG
/ ENBL = 1:
No error found,
function is enabled
FG
/ ENBL = 0:
An error has been found,
function is not enabled.
INFORMATION
If you are using a Pilz evaluation package we recommend that you use
flags M70.00 ... M88.23 for the output parameter FG/ENBL. You will need
to note the allocation of the flags to the safety subroutine numbers (input
parameter SSNR): SSNR = 1 should use flag M70.00; SSNR = 600 should
use flag M88.23.
The Appendix contains a table showing the allocation of safety subroutine
numbers to enable flags.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license