Examples – Pilz PSS SB HYD, Basic license User Manual
Page 256

8-20
Examples
Modular Block System: Hydraulic Presses
Safety gate monitoring with automatic start and manual restart,
category 2
Block used: SB066/ST_K4
Cyclical function test on the gate:
The following application requires a cyclical function test of the safety gate
(open/close safety gate).
This requirement is met by carrying out a function test using a 1/0-pulse
edge at the input parameter
MEin.
Set operating mode:
The following operating mode is set for this application:
ARSt = 0: Reset lock activated (manual restart)
The operator must reset each time the safety gate opens
(input parameter
Strt).
NFkT = 1
No function test on safety gate when PSS starts up/resets
AuSt = 1
Automatic start
WARNING!
When a safety-related device provides a start or restart signal, the start or
restart shall take place automatically only if a hazardous situation cannot
exist (EN 954, 03/97).
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license