8-42

Examples

Modular Block System: Hydraulic Presses

ESPE/AOPD in single break mode with cycle reset via a pulse at top
dead centre (TDC)

Block used: SB068/BWS_AOS

Set operating mode:
The following mode is set for this application:

OFF

= 0

ESPE/AOPD in single break mode

GdO

= 0

Enabled via a single interruption to the ESPE.

SBrk

= 1

The signal must come from a connected operating mode

DBrk

= 0

selector switch block (e.g. SB051).

SSeq

= 0

Start-up disabler / function test

Cycle reset:
In this example, the cycle is reset via a pulse at top dead centre.

Sequence:
• Cycle reset

Once the cycle is reset (resetting the cycle counter), the pulsed output
(output parameter

RdCy) will change from a 0-signal to a 1-signal.

• Start the next cycle

If

RdCy = 1, the next cycle can be started by accessing the protected

field.

DANGER!

The reset lock must be active throughout the duration of the potentially
dangerous movement.
The input parameter

ARSt should be assigned a static 0-signal (RLO-0).

This will activate the reset lock if the protected field is accessed during a
potentially dangerous movement.