Sb065: feedback loop monitoring, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual
Page 102: Standard function blocks sb065

6-40
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB065
SB065: Feedback loop monitoring
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 600
Format: Word constants KF000001 ... KF000600
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
•
GRP:
I/O-Group status flag (SafetyBUS p) containing the inputs
FBL1 and FBL2 (M116.00 for I/O-Group 0 to M116.31 for I/O-
Group 31)
If the SB is being used without SafetyBUS p, the input
parameter must be assigned RLO-1
•
ON:
Switch on contactors via output parameters
K1 and K2
ON = 0/1 pulse edge: Switch on output parameters K1 and K2
(
K1 = 1 and K2 = 1)
ON = 1/0 pulse edge: Switch off output parameters K1 and K2
(
K1 = 0 and K2 = 0)
•
FbL1:
Feedback loop N/C contact on contactor 1
•
FbL2:
Feedback loop N/C contact on contactor 2
SB065
FBL
W- SSNR
X - GRP
X - ON
X - FbL1
X - FbL2
W- TFbL
X - RSET
ENBL - X
K1
- X
K2
- X
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license