beautypg.com

Sb065: feedback loop monitoring, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual

Page 102: Standard function blocks sb065

background image

6-40

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB065

SB065: Feedback loop monitoring

Block header

Input parameters

SSNR:

Safety subroutine number
Permitted value range: 1 ... 600
Format: Word constants KF000001 ... KF000600
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).

GRP:

I/O-Group status flag (SafetyBUS p) containing the inputs
FBL1 and FBL2 (M116.00 for I/O-Group 0 to M116.31 for I/O-
Group 31)
If the SB is being used without SafetyBUS p, the input
parameter must be assigned RLO-1

ON:

Switch on contactors via output parameters

K1 and K2

ON = 0/1 pulse edge: Switch on output parameters K1 and K2
(

K1 = 1 and K2 = 1)

ON = 1/0 pulse edge: Switch off output parameters K1 and K2
(

K1 = 0 and K2 = 0)

FbL1:

Feedback loop N/C contact on contactor 1

FbL2:

Feedback loop N/C contact on contactor 2

SB065

FBL

W- SSNR
X - GRP
X - ON
X - FbL1
X - FbL2
W- TFbL
X - RSET

ENBL - X
K1

- X

K2

- X