Sb065: feedback loop monitoring, Intended use – Pilz PSS SB HYD, Basic license User Manual
Page 36

4-6
Intended Use
Modular Block System: Hydraulic Presses
Operating modes:
• Automatic start when PSS starts up or when starting I/O-Groups
(SafetyBUS p)/start-up reset when PSS is cold-started or when starting
I/O-Groups (SafetyBUS p) (start-up disabler)
• No function test/function test on the gate during start-up
(function test = opening and closing the gate)
• Automatic restart/reset to start (reset lock)
• Restart without function test/start only after function test on the gate
(reset lock) (function test = opening and closing the gate)
• Synchronisation time is selectable
INFORMATION
Input circuitry:
• Inputs should have pulsed outputs
SB065: Feedback loop monitoring
SB065 is a standard function block for the direct control and monitoring of
1 or 2 contactors up to category 4, in accordance with EN 954-1, 03/97.
INFORMATION
On SB065, the SSNR may lie in the range of 1 to 600.
Features and application areas:
• Feedback loop is monitored during the change in the switch signal and
while the contactors are in a static condition.
• Feedback loop can be monitored on two separate feedback loops of
contactors connected in series
• Feedback loop can be monitored on two separate feedback loops of
contactors connected in parallel
• Feedback loop can be monitored on group contactors
• Selectable time for feedback loop monitoring
• Parameter to suppress error messages when an I/O-Group stops
(SafetyBUS p)
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license