4-6

Intended Use

Modular Block System: Hydraulic Presses

Operating modes:

• Automatic start when PSS starts up or when starting I/O-Groups

(SafetyBUS p)/start-up reset when PSS is cold-started or when starting
I/O-Groups (SafetyBUS p) (start-up disabler)

• No function test/function test on the gate during start-up

(function test = opening and closing the gate)

• Automatic restart/reset to start (reset lock)

• Restart without function test/start only after function test on the gate

(reset lock) (function test = opening and closing the gate)

• Synchronisation time is selectable

INFORMATION
Input circuitry:
• Inputs should have pulsed outputs

SB065: Feedback loop monitoring

SB065 is a standard function block for the direct control and monitoring of
1 or 2 contactors up to category 4, in accordance with EN 954-1, 03/97.

INFORMATION
On SB065, the SSNR may lie in the range of 1 to 600.

Features and application areas:

• Feedback loop is monitored during the change in the switch signal and

while the contactors are in a static condition.

• Feedback loop can be monitored on two separate feedback loops of

contactors connected in series

• Feedback loop can be monitored on two separate feedback loops of

contactors connected in parallel

• Feedback loop can be monitored on group contactors

• Selectable time for feedback loop monitoring

• Parameter to suppress error messages when an I/O-Group stops

(SafetyBUS p)