Block header, Input parameters, Standard function blocks – Pilz PSS SB HYD, Basic license User Manual
Page 120: Sb068

6-58
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB068: Monitoring ESPE / AOPDs with guarding and control function
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
Value of DW (SSNR) = 0: No error found
•
NO_1:
N/O contact 1 of ESPE/AOPD
NO_1 = 0: Protected field broken
NO_1 = 1: Protected field clear
•
NO_2:
N/O contact 2 of ESPE/AOPD
NO_2 = 0: Protected field broken
NO_2 = 1: Protected field clear
•
OFF:
ESPE/AOPD in OFF mode
OFF = 1
GdO = 0
Guard function of ESPE/AOPD is deactivated.
SBrk = 0
The signal must come from a connected
DBrk = 0
operating mode selector switch block (SB51/52).
SB068
BWS_AOS
B - SSNR
X - NO_1
X - NO_2
X - OFF
X - GdO
X - SBrk
X - DBrk
X - RUN
X - CyRs
X - SSeq
X - ARSt
X - STyp
X - Test
X - RSET
ENBL -
X
TEST -
X
RdCy -
X
PWR
-
X
SB068
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license