Modular Block System: Hydraulic Presses
6-93
Sequential muting mode
(Muting when entering the danger area)
Fig. 6-1: Entering the danger area (sequential muting mode)
Muting signal arrangement
Position MS1/MS2 and distance A/B:
Distance B should be as long as possible, but shorter than the
length of transport vehicle W.
Required: W > B and W > A
Position MS2 and distance C:
MS2 must be located as close as possible to the ESPE/AOPD,
i.e. distance C should be as short as possible.
Position MP1:
Requires muting signal MP1.
Position MP2:
Muting signal MP2 is optional and is used to detect vehicles
leaving the danger area (please refer to “Parallel mode”).
If the muting signal MP2 is used, it must be operated at the
same time as MP1.
If muting signal MP2 is not being used, the input parameter
MP2 should be assigned RLO-0 (M 110.00).
MS1
MS2
MP2
ESPE/
AOPD
MP1
ESPE/
AOPD
W
B
C
C
A
Transport
Vehicle
Danger Area
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license