beautypg.com

Error messages – Pilz PSS SB HYD, Basic license User Manual

Page 83

background image

Modular Block System: Hydraulic Presses

6-21

Error messages

Any fault that is detected will be stored in the corresponding error data
word (

SSNR) of DB 015 (1st data block), until the fault has been fully dealt

with.

• Error messages in DB 015

- Bit 00:

T1 N/O and N/C contact open
Remedy: Check input button, cable, input card and all
conditions, then reset (input parameter

RSET)

- Bit 01:

T1 N/O and N/C contact closed
Remedy: Check input button, cable, input card and all
conditions, then reset (input parameter

RSET)

- Bit 02:

T2 N/O and N/C contact open
Remedy: Check input button, cable, input card and all
conditions, then reset (input parameter

RSET)

- Bit 03:

T2 N/O and N/C contact closed
Remedy: Check input button, cable, input card and all
conditions, then reset (input parameter

RSET)

- Bit 04:

Two-hand control circuit/console selected, but the console is
disconnected
Remedy: Check switch, cable, input card and all conditions,
then reset (input parameter

RSET)

- Bit 05:

Two-hand control circuit/console is deselected, but the console
is connected
Remedy: Check switch, cable, input card and all conditions,
then reset (input parameter

RSET)

- Bit 08: Reset (input parameter

RSET) pressed too soon or constantly

pressed
Remedy:
If

RSET input has not been set too early and is contantly high:

Check switch, cable and input card, then reset (input
parameter

RSET)

If

RSET input has been set too early: reset again (input

parameter

RSET)