Any fault that is detected will be stored in the corresponding error data
word (
SSNR) of DB 015 (1st data block), until the fault has been fully dealt
with.
• Error messages in DB 015
- Bit 00:
T1 N/O and N/C contact open
Remedy: Check input button, cable, input card and all
conditions, then reset (input parameter
RSET)
- Bit 01:
T1 N/O and N/C contact closed
Remedy: Check input button, cable, input card and all
conditions, then reset (input parameter
RSET)
- Bit 02:
T2 N/O and N/C contact open
Remedy: Check input button, cable, input card and all
conditions, then reset (input parameter
RSET)
- Bit 03:
T2 N/O and N/C contact closed
Remedy: Check input button, cable, input card and all
conditions, then reset (input parameter
RSET)
- Bit 04:
Two-hand control circuit/console selected, but the console is
disconnected
Remedy: Check switch, cable, input card and all conditions,
then reset (input parameter
RSET)
- Bit 05:
Two-hand control circuit/console is deselected, but the console
is connected
Remedy: Check switch, cable, input card and all conditions,
then reset (input parameter
RSET)
- Bit 08: Reset (input parameter
RSET) pressed too soon or constantly
pressed
Remedy:
If
RSET input has not been set too early and is contantly high:
Check switch, cable and input card, then reset (input
parameter
RSET)
If
RSET input has been set too early: reset again (input
parameter
RSET)
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license