Pilz PSS SB HYD, Basic license User Manual
Page 275

8-39
Modular Block System: Hydraulic Presses
SafetyBUS p example
INFORMATION
On decentralised DI inputs, input statuses are only available to the PSS
after a group start has taken place. However, due to the inversion of the
input signal between sensor connections 3 and 4, input parameter
S1 will
show RLO = 1 and input parameter
S2 RLO = 0. The inverted input
statuses will therefore need to be AND-linked to the respective group
flags.
LN
E33.00
PSEN_CH1
Safety gate contact channel 1
U
M116.31 SBp_IO-Group
SBp Status-M I/O-Group 31
=
M099.00 MPSENCH1
Flag for s/gate signal channel 1
L E33.01 PSEN_CH2
Safety gate contact channel 2
U
M116.31 SBp_IO-Group
SBp Status-M I/O-Group 31
=
M099.01 MPSENCH2
Flag for s/gate signal channel 2
CAL SB066
SB066
ST_K4
B - SSNR
X - S1
X - S2
W - SyTi
X - MEin
X - Strt
X - ARSt
X - AuSt
X - NFkT
FG - X - M070.02
KB003
-
M99.00
.MPSENCH1
-
M99.01
.MPSENCH2
-
KF03000 .Syn.Time
-
M110.00 .RLO_0
-
E0.03
.Reset
-
M110.00 .RLO_0
-
M110.00 .RLO_0
-
M110.01 .RLO_1
-
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license