8-39

Modular Block System: Hydraulic Presses

SafetyBUS p example

INFORMATION
On decentralised DI inputs, input statuses are only available to the PSS
after a group start has taken place. However, due to the inversion of the
input signal between sensor connections 3 and 4, input parameter

S1 will

show RLO = 1 and input parameter

S2 RLO = 0. The inverted input

statuses will therefore need to be AND-linked to the respective group
flags.

LN

E33.00

PSEN_CH1

Safety gate contact channel 1

U

M116.31 SBp_IO-Group

SBp Status-M I/O-Group 31

=

M099.00 MPSENCH1

Flag for s/gate signal channel 1

L E33.01 PSEN_CH2

Safety gate contact channel 2

U

M116.31 SBp_IO-Group

SBp Status-M I/O-Group 31

=

M099.01 MPSENCH2

Flag for s/gate signal channel 2

CAL SB066

SB066

ST_K4

B - SSNR
X - S1
X - S2
W - SyTi
X - MEin
X - Strt
X - ARSt
X - AuSt
X - NFkT

FG - X - M070.02

KB003

-

M99.00

.MPSENCH1

-

M99.01

.MPSENCH2

-

KF03000 .Syn.Time

-

M110.00 .RLO_0

-

E0.03

.Reset

-

M110.00 .RLO_0

-

M110.00 .RLO_0

-

M110.01 .RLO_1

-