Block header, Input parameters, Standard function blocks – Pilz PSS SB HYD, Basic license User Manual
Page 190: Sb087

6-128
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB087: Driving/monitoring the position of a single hydraulic valve
(poppet and directional control valve)
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
Value of DW (
SSNR) = 0: No error found
•
ON:
Start signal for “Operate valve”
ON = 0:
Valve switched off
ON = 0/1 pulse edge: Switch valve on
ON = 1:
Valve switched on
ON = 1/0 pulse edge: Switch valve off
The valve cannot be switched on if the block has detected a
fault (reset lock).
The valve can only be switched on if it is in its start (off)
position (see input parameter
S).
•
S:
Acknowledgement of valve position
S = 1:
Valve in its start position (valve de-energised,
acknowledgement from valve is present)
INFORMATION
If the valve is acknowledged via a switch, the supply to this switch must
be from test pulses.
SB087
H_VALV_S
B - SSNR
X - ON
X - S
W - TOn
W - TOff
X - VTyp
X - RSET
ENBL - X
Y
- X
ERR - X
SB087
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license