Sb092: enable switch, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual
Page 220: Standard function blocks sb092

6-158
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB092
SB092: Enable switch
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
Value of DW (SSNR) = 0: no error found
•
ON:
Switch operating mode on/off (enable function)
ON = 0: Operating mode switched off
ON = 0/1 pulse edge: Switch on operating mode
•
NC:
N/C contact
(please refer to “Switching diagrams”).
•
NO:
N/O contact
(please refer to “Switching diagrams”).
INFORMATION
Both contacts
NC and NO should be provided with different
test pulse outputs (test pulses).
•
AuSt:
Automatic start/start-up lock when the PSS starts up
AuSt = 0:
Start-up disabled when PSS starts up
When the PSS starts up, a reset via the input
parameter
RSET is required. To set the start-up
lock on the SB, the input parameter should be
assigned RLO-0 (M 110.00).
SB 092
ENBL_DEV
B - SSNR
X - ON
X - NC
X - NO
X - AuSt
X - ARst
X - RSET
ENBL - X
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license