6-47

Modular Block System: Hydraulic Presses

Block parameters:

Muting Lamp: Segment 00

KB002

- SSNR

M 116.01 SBp-Group_01

- GRP

M 081.01 .Muting_Active

- ON

E 32.04 .FL1

- FbL1

E 32.05 .FL2

- FbL2

M 110.00 .RLO-0

- 1OUT

E 33.00 .Reset-Lamps

- RSET

Muting: Segment 01

KB001

- SNR

E 32.06 .AOPD-NO 1

- NO_1

E 32.07 .AOPD-NO 2

- NO_2

E 32.00 .Muting-sensor S1 - MS1
E 32.01 .Muting-sensor S2 - MS2
E 32.02 .Muting-sensor P1 - MP1
E 32.03 .Muting-sensor P2 - MP2
KF 005000

- TS12

KF 000500

- TPSy

KF 001000

- TInt

KF 000015

- TMut

KF 002000

- TOPD

M 110.00 .RLO-0

- TOff

M 110.00 .RLO-0

- AuSt

M 110.01 .RLO-1

- SMd2

MW 080.00 .Aux.Value

- THlp

E 33.00 .Reset-Muting

- RSET

Safety: Segment 02

:L

M 81.00 .EnableMuting

:U M 81.02 .EnableLamps
:=

M 90.00 .EnableWhole

ENBL - M 081.00 .EnableMuting
MAct

- M 081.01 .Muting_Active

SB097

MUT_LAMP

ENBL - M 081.02 .EnableLamps
WARN - M 081.03 .Lamp def.
LMP1 - A 32.06 .Lamp 1 (A 32.02)
LMP2 - A 32.07 .Lamp 2 (A 32.03)

SB072

MUTING