Modular Block System: Hydraulic Presses
Standard Function Blocks
SB072
Wiring the output parameters
Muting must be displayed through an LED (output parameter
MAct). This
LED must be safely monitored to ensure it functions correctly (EN 61 496-1
Section 7.1, 06/98).
For this reason the muting LED should be connected to a dual-pole output
(e.g. PSS DI2O Z module) or use standard function block SB097.
Operating modes
Terminology
Muting ON
“Muting ON” is the switch condition for switching on the muting function. If
muting is switched on, the output parameter
MAct will be high and time
monitoring will be running (input parameter
TMut / TOPD).
Muting OFF
“Muting OFF” is the switch condition for ending the muting function. When
the muting function is ended the output parameter
MAct will be low.
Muting Start-Up
“Muting Start-Up” is the switch condition for switching on the muting
function when the PSS is cold-started or reset using the key switch (input
parameter
RSET).
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license