Intended use of the standard function blocks, Sb051: operating mode selector switch 1 from 8, Intended use – Pilz PSS SB HYD, Basic license User Manual
Page 32

4-2
Intended Use
Modular Block System: Hydraulic Presses
Intended use of the standard function blocks
SB051: Operating mode selector switch 1 from 8
SB051 is a standard function block designed to monitor the position of
lockable standard operating mode selector switches.
Safe coding is achieved by means of the selection process “1 from 8”.
Features:
• Maximum of 8 operating modes are possible
• Break-free switchover within the adjustable contact switchover time
Input circuitry:
• 1 input is required per operating mode
INFORMATION
If possible you should use the PSS(1) DI2 as input module.
If this is not possible, the inputs must use test pulses.
This manual is related to the following products:
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license