beautypg.com

Intended use of the standard function blocks, Sb051: operating mode selector switch 1 from 8, Intended use – Pilz PSS SB HYD, Basic license User Manual

Page 32

background image

4-2

Intended Use

Modular Block System: Hydraulic Presses

Intended use of the standard function blocks

SB051: Operating mode selector switch 1 from 8

SB051 is a standard function block designed to monitor the position of
lockable standard operating mode selector switches.

Safe coding is achieved by means of the selection process “1 from 8”.

Features:

• Maximum of 8 operating modes are possible

• Break-free switchover within the adjustable contact switchover time

Input circuitry:

• 1 input is required per operating mode

INFORMATION
If possible you should use the PSS(1) DI2 as input module.
If this is not possible, the inputs must use test pulses.