Dial-backup connect-timeout Page 905
Page 905
Command Reference Guide
PPP Interface Configuration Command Set
61200990L1-35E
Copyright © 2005 ADTRAN
905
dial-backup connect-timeout
Use the dial-backup connect-timeout command to specify the number of seconds to wait for a connection
after a call is attempted before trying to call again or dialing a different number. It is recommended this
number be greater than 60. For more detailed information on PPP dial-backup functionality, refer to the
Functional Notes and Technology Review sections of the command.
Syntax Description
Selects the amount of time (in seconds) that the router will wait for a connection
before attempting another call (valid range: 10 to 300).
Default Values
By default, the dial-backup connect-timeout period is set to 60 seconds.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 1.1
Command was introduced.
Release 5.1
Command was expanded to include the PPP interface.
Usage Examples
The following example configures the AOS to wait 120 seconds before retrying a failed dial-backup call:
(config)#interface ppp 1