connect-sequence
Use the connect-sequence command to provide instructions to the interface on how to use the resource
pool and telephone numbers to connect to demand destinations. Use the no form of this command to
restore the default values.
Variations of this command include the following:
connect-sequence
connect-sequence
connect-sequence
busyout-threshold
connect-sequence
connect-sequence
busyout-threshold
connect-sequence
connect-sequence
connect-sequence
Syntax Description
Specifies the number for this connection specification entry. Range: 1 to 65,535.
Specifies the telephone number to dial when using this connection. The dial
string is limited to 20 digits.
forced-analog
Specifies that only analog resources may be used.
forced-isdn-56k
Specifies that only ISDN resources may be used. Call is placed using ISDN 56k.
forced-isdn-64k
Specifies that only ISDN resources may be used. Call is placed using ISDN 64k.
isdn-56k
Specifies any dial resource may be used if ISDN 56k call-type is used.
isdn-64k
Specifies any dial resource may be used if ISDN 64k call-type is used.
busy-threshold
activation attempt that must fail before it is skipped until the next activation
attempt.
Default Values
By default any dial resource may be used.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 11.1
Command was introduced.