Frame-relay intf-type [dce | dte | nni – ADTRAN 5000 Series User Manual
Page 696

Command Reference Guide
Frame Relay Interface Config Command Set
61200990L1-35E
Copyright © 2005 ADTRAN
696
frame-relay intf-type [dce | dte | nni]
Use the frame-relay intf-type command to define the Frame Relay signaling role needed for the endpoint.
Use the no form of this command to return to the default value.
Syntax Description
dce
Specifies DCE or network-signaling role. Use this interface type when you need
the unit to emulate the frame switch.
dte
Specifies DTE or user-signaling role. Use this interface type when connecting to a
Frame Relay switch (or piece of equipment emulating a frame switch).
nni
Configures the interface to support both network and user signaling (DTE or DCE)
when necessary.
Default Values
By default, frame-relay intf-type is set to dte.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1
Command was introduced.
Usage Examples
The following example configures the Frame Relay endpoint for DCE signaling:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay intf-type dce