305
clock [auto-correct-dst | no-auto-correct-dst]
The clock auto-correct-dst command allows the unit to automatically correct for Daylight Saving Time
(DST). Use the clock no-auto-correct-dst command to disable this feature.
Syntax Description
auto-correct-DST
Configures the unit to automatically correct for DST.
no-auto-correct-DST
Disables DST correction.
Default Values
By default DST correction takes place automatically.
Applicable Platforms
This command applies to the NetVanta 300, 1000, 1000R, 2000, 3000, 4000, and 5000 and
Total Access 900 Series units.
Command History
Release 6.1
Command was introduced.
Release 11.1
Command was added to the Global command set.
Functional Notes
Depending on the clock timezone chosen (see
for more information)
one-hour DST correction may be enabled automatically. You may override this default using this
command.
Usage Examples
The following example allows for automatic DST correction:
(config)#clock auto-correct-dst
The following example overrides the one-hour offset for DST:
(config)#clock no-auto-correct-dst