Command Reference Guide

T1 Interface Configuration Command Set

61200990L1-35E

Copyright © 2005 ADTRAN

604

clock source [internal | line | through | through ]

Use the clock source command to configure the source timing used for the interface. Use the no form of
this command to return to the default value.

Syntax Description

internal

Configures the unit to provide clocking using the internal oscillator.

line

Configures the unit to recover clocking from the T1 circuit.

through

Configures the unit to recover clocking from the circuit connected to the DSX-1
interface.

through t1 > Configures the unit to recover clocking from the alternate interface. Only valid

on T1 systems with multiple T1 interfaces and a single clock source.

Default Values

By default, the clock source is set to line.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series and Total Access 900 Series
units.

Command History

Release 1.1

Command was introduced.

Functional Notes

When operating on a circuit that is providing timing, setting the clock source to line can avoid errors such
as Clock Slip Seconds (CSS).

Usage Examples

The following example configures the unit to recover clocking from the primary circuit:

(config)#interface t1 1/1

(config-t1 1/1)#clock source line