beautypg.com

Connect-sequence attempts

Page 643

background image

Command Reference Guide

Demand Interface Configuration Command Set

61200990L1-35E

Copyright © 2005 ADTRAN

643

connect-sequence attempts

Use the connect-sequence attempts command to limit the number of times the connect sequence will
cycle when its entries are unable to establish a connection. When the maximum number of attempts are
exhausted, the interface will go into recovery mode. Refer to connect-sequence interface-recovery
[retry-interval | max-retries ]

on page 644

for more information. Use the no form of

this command to restore the default values.

Syntax Description

Specifies the number of times the connect sequence will cycle through its entries
if it is unable to make a connection. Range is 0 to 65,535.

Default Values

By default the connect-sequence attempts are unlimited.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.

Command History

Release 11.1

Command was introduced.

Usage Examples

The following example instructs demand interface 1 to attempt its connection sequence 500 times:

(config)#interface demand 1

(config-demand 1)#connect-sequence attempts 500