beautypg.com

ADTRAN 5000 Series User Manual

Page 630

background image

Command Reference Guide

T3 Interface Configuration Command Set

61200990L1-35E

Copyright © 2005 ADTRAN

630

test-pattern [clear | insert | ones | p215 | p223 | zeros]

Use the test-pattern command to activate the built-in pattern generator and begin sending the selected test
pattern toward the network. This pattern generation can verify a data path when used in conjunction with
an active loopback. Use the no form of this command to cease pattern generation.

Syntax Description

clear

Clears the test pattern error count.

insert

Inserts an error into the currently active test pattern. Display the injected error
result using the show test pattern command.

ones

Generates a test pattern of continous ones.

p215

Generates a pseudorandom test pattern sequence based on a 15-bit shift register.

p223

Generates a pseudorandom test pattern sequence based on a 23-bit shift register.

zeros

Generates a test pattern of continous zeros.

Default Value

No default value is necessary for this command.

Applicable Platforms

This command applies to the NetVanta 5000 Series.

Command History

Release 6.1

Command was introduced.

Usage Example

The following example inserts a p215 test pattern:

(config)#interface t3 1/1

(config-t3 1/1)#test-pattern 2^15 insert