Worksheet method – Edwards Signaling eFSA250 User Manual
Page 229

Appendix B: Worksheets
E-FSA64 and E-FSA250 Technical Reference Manual
217
Worksheet method
Use this worksheet to determine the maximum cable length of a notification
appliance circuit for a given number of appliances.
Use this worksheet only if all the appliances are regulated. That is, they must
have a minimum operating voltage of 16 V. For other appliances, use the
“Equation method.”
NAC cable length
NAC1
NAC2
NAC3
NAC4
Total operating current [1]
A
Load factor (eFSA64 panel)
×
0.20
0.20
0.20
0.20 V/A
Load factor (eFSA250 panel)
0.24
0.24
0.24
0.24
Load voltage drop
=
V
Source voltage
20.4
20.4
20.4
20.4
V
Load voltage drop
−
V
Minimum voltage
=
V
Regulated appliance voltage
−
16.0
16.0
16.0
16.0
V
Voltage drop [2]
=
V
Total operating current
÷
A
Maximum resistance
=
Ω
Wire resistance (Ω/ft) [3]
÷
Maximum wire length
=
ft.
÷
2
2
2
2
Maximum cable length
=
ft.
[1] Total of the maximum operating currents for all appliances as specified for FWR power. See
the appliance installation sheets for operating currents.
[2] This voltage drop is valid for regulated notification appliances only. For unregulated
appliances, see “Equation method” on page 218.
[3] Use the manufacturer’s published wire resistance expressed in ohms per foot. For typical
values, see Table 46 on page 218.