beautypg.com

Edwards Signaling Genesis Temporal Horn User Manual

Genesis temporal horn installation sheet, Description, Installation

background image

© 2013 UTC Fire & Security. All rights reserved.

1 / 4

P/N 3100558 • REV 04 • REB 30JAN13

Genesis Temporal Horn Installation Sheet

Description

The Genesis Temporal Horn is an audible fire alarm
notification appliance designed for indoor walls. See Table 1
for a list of model numbers.

The horn includes field configurable jumper options for
selecting:

Temporal or steady horn output (see Figure 1 item 1)

High dB or low dB output (see Figure 1 item 2)

Table 1: Models

Description

Number

Temporal horn,
white

ADTG1-HD

MG1-HD

EG1-HD

XLSG1-HD

G1-HD

ZG1-HD

G1-HD-LG

Temporal horn,
white, with FIRE marking

ADTG1F-HD

MG1F-HD

EG1F-HD

XLSG1F-HD

G1F-HD

ZG1F-HD

G1F-HD-LG

Temporal horn,
red

ADTG1R-HD

MG1R-HD

EG1R-HD

XLSG1R-HD

G1R-HD

ZG1R-HD

G1R-HD-LG

Temporal horn,
red, with FIRE marking

ADTG1RF-HD

MG1RF-HD

EG1RF-HD

XLSG1RF-HD

G1RF-HD

ZG1RF-HD

G1RF-HD-LG

Trim plate,
white

ADTG1T

MG1T

EG1T

XLSG1T

G1T

ZG1T

G1T-LG

Trim plate,
white, with FIRE marking

ADTG1T

MG1T

EG1T

XLSG1T

G1T

ZG1T

G1T-LG

Trim plate,
red

ADTG1RT

MG1RT

EG1RT

XLSG1RT

G1RT

ZG1RT

G1RT-LG

Trim plate,
red, with FIRE marking

ADTG1RT

MG1RT

EG1RT

XLSG1RT

G1RT

ZG1RT

G1RT-LG

Installation

Install this device in accordance with applicable requirements
in the latest editions of the NFPA codes and standards; the
National Building Code of Canada; the Canadian Electrical
Code, Part 1
, Section 32, and in accordance with the local
authorities having jurisdiction.

Caution:

Electrical supervision requires breaking the wire run

at each terminal. Do not loop the signaling circuit field wires
around the terminals.

To install the horn:

1. Remove the cover by depressing both tabs on the top of

the unit with a small screwdriver and twisting slightly.

2. Set the horn signal and sound output level to desired

settings. See Figure 1.

3. Connect the horn terminals to the signal circuit field wiring.

Observe polarity for the unit to function properly. See
Figure 1.

4. Mount the unit onto a compatible electrical box, making

sure not to overtighten the mounting screws.

5. Replace the cover by aligning at the bottom, then

snapping in at the top.

6. Test the unit for proper operation.

Figure 1: Horn settings

J2 J3

J1

1

2

1.

To change the horn signal from temporal to steady, cut from circle
J2 to edge of circuit board

2.

To change the horn sound output level from high dB to low dB.
cut J3 by snipping the board trace between holes