Edwards Signaling 2315 Series User Manual
2315 series, Panel door magnetic contact, Installation instructions
2315 Series
Panel Door Magnetic Contact
Models: 2315A, 2317A
Installation Instructions
Mounting
Caution:
Locate the magnet away from manual
handles and latches to prevent it from being used
as a foothold or handle to close the door.
1. Slide the slot of the switch over the beveled-edge of
the L-bracket and snap it tightly into place as shown in
Figure 1. Screw down firmly.
Figure 4
2. Align the magnet with the switch and use screws to
attach it to the door as shown in Figure 2. The switch
and magnet must be aligned within 1/2 inch of each
other to prevent false alarms.
3. Connect the switch wires to the alarm system and test to
verify proper operation.
Important:
The contact should be mounted at
least 13 inches from the floor. If other track-
mounted devices interfere, mount the switch under
them.
Figure 1
Figure 2
Optional:
Use the existing roller-track bolts to
mount the switch without using the L-Bracket as
shown in Figure 3.
Figure 3
The magnet can be attached at
two different elevations from
the door.
Fits standard 2” roller-tracks for
sectional/panel overhead
doors.
elevation 1
elevation 2
1/4 to 1/2”
spacing