Edwards Signaling 101XBRM Series User Manual

Description, Mechanical specifications, Installation

background image

Figure 1. Dimensions

Description

Edwards AdaptaLight Series 101XBRM Stackable Beacon

is a unique signaling appliance which can contain up to five

modules, stacked onto a single AdaptaLight Base Unit (as

illustrated above). The 101XBRM series can be combined

or stacked with any of the models shown in Table 2 only if

modules have same input voltage. The 101XBRM LED Se-

ries is supplied in steady-on mode but offers a field-selectable

65 fpm flash mode. Up to five modules can be used in any

position in the AdaptaLight Stackable Beacon.
The AdaptaLight base unit (101BS) contains a mini pulsating

horn rated 85 dB at 10 feet (3.05 m). This horn can operate

as a sixth independent signal or with any one of the stacked

modules shown in Table 2. The base unit has a screw-type

terminal strip for positive hard wiring. Each module in the

stack is electrically interconnected through solid copper

busses and mating contacts to withstand vibration. Each is

positively connected to the one below it by a solid through-

bolt for mechanical integrity.
AdaptaLight is UL and cUL listed for direct surface or pipe

mounting in non-hazardous dust and outdoor applications.

The AdaptaLight may be mounted vertically with lenses facing

up or with lenses facing down (on ceiling). The AdaptaLight

is not suitable for outdoor installations when mounted with

the lenses facing down. The AdaptaLight must never be

mounted horizontally. Assemble and install in accordance

with these instructions.
The AdaptaLight modules have double fresnel polycarbonate

lenses available in a variety of colors, each providing a 360°

non-shadowed light pattern.

Mechanical Specifications

Outdoor Locations

Temperature Ratings ........... -31F to +150F (-35C to +66C)

PLC Compatibility
The electrical input load requirements for PLC compatible

signaling devices are listed in Table 1. Signaling devices

may be directly connected to output cards that meet these

input load requirements. Unit is PLC compatible only when

in steady mode.

Installation

To prevent electrical shock, do not connect

power until instructed to do so.

WARNING

This equipment must be installed by a qualified electrician in

accordance with the latest edition of the National Electrical

Code and applicable local codes.
1. Mount the base vertically either facing up or down using

one of the following procedures (Figures 2 and 3).

NOTE: For indoor applications, the base may be direct

surface mounted, mounted on a 4" (102 mm)

octagon box, or mounted on 1/2" NPT conduit.

For outdoor (weatherproof) applications, the base

must be conduit mounted vertically facing up.

a. Loosen the screw in the clamp ring, remove ring and

set aside.

NOTE: A permanently affixed gasket is supplied on the

base. Use care when handling the base unit to

prevent tearing of the gasket.

7 3/4” (197 mm)

3 lbs (1.4 kg)

11 3/8” (289 mm)

4 lbs (1.8 kg)

15” (381 mm)

5 lbs (2.3 kg)

18 5/8” (473 mm)

6 lbs (2.7 kg)

22 1/4” (565 mm)

7 lbs (3.2 kg)

P/N 3101631 ISSUE 3

© 2010